• 2D drawing of LSZS Low Stress Studded Inserts, featuring a studded design for additional fastening capabilities.
  • LSZS dimension dwg
  • 2D drawing of LSZS Low Stress Studded Inserts, featuring a studded design for additional fastening capabilities.
  • LSZS dimension dwg

LSZS Low Stress Studded Inserts Metric


LSZS Studded Insert Features

  • Rounded knurl pattern reduces stress in notch sensitive amorphous thermoplastics.
  • Rapid self–aligning installation using heat.
  • Double–ended to assist automatic feeding by eliminating the need for orientation during installation.
  • Knurl pattern provides high torque–out resistance.
  • Available in a wide variety of thread sizes, stud lengths and options.
Download PDF

Loading Parts

General
Insert ThreadInsert Thread CodeL Insert LengthInsert Length CodeBossA Head ThicknessC Head DiameterD Insert DiameterP Pilot Diameter
B Hole Dia. +0.10 -0.00W Minimum Wall Thickness
M2 x 0.4M23.903.903.201.400.514.803.503.10
M2.5 x 0.45M2.55.805.804.001.800.585.504.403.90
M3 x 0.5M35.805.804.001.800.585.504.403.90
M3.5 x 0.6M3.57.107.104.802.100.746.405.204.70
M4 x 0.7M48.108.105.602.400.897.106.105.50
M5 x 0.8M59.509.506.402.801.077.906.906.30
M6 x 1.0M612.7012.708.003.601.329.508.507.90
M8 x 1.25M812.7012.709.605.001.3211.1010.009.50
Stud Length
Stud ThreadStud Thread CodeD Insert DiameterS – Stud Length
5.006.008.0010.0012.0014.0016.0018.0020.0025.00
Stud Length Code
M2 x 0.4M23.505.006.008.00
M2.5 x 0.45M2.54.405.006.008.0010.00
M3 x 0.5M34.405.006.008.0010.0012.00
M3.5 x 0.6M3.55.205.006.008.0010.0012.0014.00
M4 x 0.7M46.105.006.008.0010.0012.0014.0016.00
M5 x 0.8M56.905.006.008.0010.0012.0014.0016.0018.0020.00
M6 x 1.0M68.506.008.0010.0012.0014.0016.0018.0020.0025.00
M8 x 1.25M810.008.0010.0012.0014.0016.0018.0020.0025.00
Boss Design Recommendation
The LSZ Low Stress Zert is designed to be installed into a straight hole with a 0.5° inclusive taper. The top of the hole should not be countersunk or counterbored as this will decrease the insert’s performance. The recommended hole size applies at the point reached by the bottom of the insert. Molded holes should be used wherever possible as drilled holes may result in diminished performance. Minimum boss wall thicknesses shown are for reference and may vary depending on the type of plastic.
Installation
Pre-heating is the recommended installation method. The insert should be hot enough to soften the plastic without melting it to avoid flash around the top. Avoid excessive pressure that would force an insert into a hole without allowing the plastic to properly soften and flow around the insert features.